Arizona · Boilers

The boiler inspection rules in force in Arizona now.

Arizona Boiler Act (A.R.S. Title 23, Ch. 2, Art. 11) + A.A.C. R20-5 Article 4 (boilers, lined hot-water heaters, direct-fired jacketed steam kettles). Enforced by ICA/ADOSH Boiler Safety Section; since Jul 1, 2017 certificate inspections are performed only by authorized third-party or insurer inspection agencies (A.R.S. 23-485). Checked on the primary source; the state record was last reviewed 2026-11-12.

Explore Arizona by location and topic

Boilers in Arizona

Checked on the source
In force

Arizona Boiler Act (A.R.S. Title 23, Ch. 2, Art. 11) + A.A.C. R20-5 Article 4 (boilers, lined hot-water heaters, direct-fired jacketed steam kettles)

Power boilers: annual internal certificate inspection plus external about six months apart; high-temperature water boilers yearly; low-pressure heating boilers and jacketed kettles every two years; hot-water boilers to 160 psi/250F and large lined heaters: initial only. Certificate posted on site (R20-5-407). No state boiler-operator license.

Source: primary document

Who enforces it

ICA/ADOSH Boiler Safety Section; since Jul 1, 2017 certificate inspections are performed only by authorized third-party or insurer inspection agencies (A.R.S. 23-485)

Statewide layer. County and city amendments sit on top; confirm the local office for the address.

What changes next

In force

In force; ICA Boiler Safety FAQ re-read Oct 26, 2026 (power boilers: annual internal plus external about six months apart; low-pressure heating boilers every two years; lined hot-water heaters initial inspection only; certificate posted per R20-5-407); no 2026 change listed

The federal layer

There is no federal boiler certificate; the state program below is the whole obligation, with the ASME Boiler and Pressure Vessel Code and the National Board Inspection Code as the referenced standards.

What a building has to do

1 recurring duties

These apply when the building has the equipment or fits the type named. The frequency is the standard one; your local official can set a stricter one, so confirm it for the address.

Annual
Boiler: certificate inspection per state programState boiler law · State boiler inspection program · Not yet checked line by line against the source.

Questions about the boiler inspection rules in Arizona

Which boiler inspection rules apply in Arizona today?

Arizona Boiler Act (A.R.S. Title 23, Ch. 2, Art. 11) + A.A.C. R20-5 Article 4 (boilers, lined hot-water heaters, direct-fired jacketed steam kettles). Power boilers: annual internal certificate inspection plus external about six months apart; high-temperature water boilers yearly; low-pressure heating boilers and jacketed kettles every two years; hot-water boilers to 160 psi/250F and large lined heaters: initial only. Certificate posted on site (R20-5-407). No state boiler-operator license.

Who enforces the boiler inspection rules in Arizona?

ICA/ADOSH Boiler Safety Section; since Jul 1, 2017 certificate inspections are performed only by authorized third-party or insurer inspection agencies (A.R.S. 23-485).

What changes next for the boiler inspection rules in Arizona?

Nothing is scheduled. The rule above stays in force until the state adopts a newer edition or amends the program; AHJ Radar re-checks the source weekly.

Other areas in Arizona

Everything in force in Arizona

Free reference. No account is needed. Membership — Coming soon.