Florida underground storage tanks: 4 in 10 inspected facilities out of compliance

Florida's Department of Environmental Protection inspected 3,573 underground storage tank facilities in the year ending September 30, 2025 and found 60.66% in significant compliance with Chapter 62-761 of the Florida Administrative Code. The rest, roughly four in ten, were not. A hotel or condominium with an underground generator fuel tank is one of the 9,384 facilities in this program.

Source: Florida Department of Environmental Protection, Annual Summary on Underground Storage Tanks, Federal Fiscal Year ending September 30, 2025. Last checked by AHJ Radar: November 4, 2026.

The numbers

MeasureFFY 2025
Underground storage tank facilities9,384
Underground storage tanks21,475
Facilities inspected3,573
Significant compliance rate60.66%, defined as the percent of facilities in technical compliance with Chapter 62-761, F.A.C.
Releases reported118, of which 25 were later found not to be from an underground tank
Confirmed releases93

What this means for a hotel or a condominium

Chapter 62-761 applies to underground tanks above 110 gallons that hold regulated substances, and a diesel tank feeding an emergency generator is the usual way a building ends up in it. Technical compliance is the paperwork and the hardware together: registration, release detection records every month, the annual test of the detection devices, containment integrity, financial responsibility and a trained operator. A 60.66% rate means the inspector who arrives expects to find something, and the common findings are the monthly records that were not kept rather than a leaking tank. Aboveground tanks over 550 gallons fall under the companion rule, Chapter 62-762, with the same registration and inspection pattern.

What is not on this page, and why

DEP's summary does not separate release-detection from release-prevention compliance, does not list enforcement actions, and does not break the figures down by county or facility type. Aboveground tank statistics are not in this document. Confirm your tank's status with the county's tank inspection program (DEP contracts most inspections to counties) and your registered tank contractor.

Keep this current. The free digest carries the next release of this data the day it is published, a reminder before each deadline, and the Monday issue of everything that changed, each with its official source.
Get the free digest

AHJ Radar™ is a trademark of Mason Mathews Facility Assurance, LLC. Official sources read daily since September 2026; every entry names its source. Content and compilations © 2026 Mason Mathews Facility Assurance, LLC, for personal and internal use under the Terms of Use; no redistribution or resale.

Reference only. This page restates a published official document; it is not legal advice and not an assessment of any property. Confirm requirements with the official text linked above, your authority having jurisdiction and your own counsel. Mason Mathews Facility Assurance, LLC · all reference pages · how our monitor reads sources.